Rma-303 direct charge - maintenance – Ransburg RMA Direct A12867 User Manual

Page 76

Advertising
background image

RMA-303 Direct Charge - Maintenance

73

LN-9266-11.3

er body. Align the mark on the turbine with the
mark on the atomizer body. Install the turbine
retaining ring and o-ring by hand. Use the
spanner wrench to tighten an additional 1/8-
1/4 turn. (Lightly lubricate O-ring with petrole-
um jelly.) Check centering of fluid tube. If flu-
id tube is centered, the turbine is fully seated.
If not, check tightness with spanner wrench. If
tube is not centered, again remove turbine and
check for causes, such as an O-ring fell off,
fiber optic not fully installed, foreign material
on seating surface, etc. Reinstall and recheck
tube centering.

Fluid Tip Removal / Replacement

Removal

To remove the fluid tips, use the tip/tube re-
moval tool (A11229-00). Insert the tool over
the tip and engage the four (4) prongs of the
tool into the four (4) slots in the tips (see “Fluid
Tip Removal” figure).

A11229-00
TOOL

FLUID

TIP

ENGAGE

PRONGS INTO

SLOTS

Fluid Tip Removal

N O T E

To remove, turn the tip CLOCKWISE. The
thread on the tip is left hand.

Fluid Tip

The fluid tip may be removed either with the
turbine in place, or the turbine off the unit.
“Fluid Tip” figure shows removing the tip with
the turbine in place.

A11229-00
TOOL

Fluid Tip Removal

This allows removal and replacement of the
fluid tip while the applicator is on-line.

Replacement

Ensure the tip openings are fully open and
clean. Apply an O-ring lubricant to the O-ring
to help hold it in place on the fluid tip. Insert
the O-ring into the undercut groove on the tip.