Table 2 - Node Adapter + LECU4012-00
PLC I/O - NPB Mode (Dipswitch SW2-1 On) (Cont.)
** ATOMIZER STATUS WORD
DEFINITION
BIT
STATUS
Bearing Air (8-bits)
Overspeed
Underspeed
Loss of Feedback
Invalid Data Input
Low Bearing Air
Bell Running
Out of Tolerance
(Not Used)
00-07
08
09
10
11
12
13
14
15
* MICROPAK STATUS
WORD DEFINITION
BIT
STATUS
00
01
02
03
04
05
06
07
08
09
10
11
12
13-15
HV Held In Reset
HV Ready
HV On
Di/dt Fault
HV Overload
Feedback Fault
Sequence
Local
Fluid Trigger Active
Air Trigger Active
Di/dt Enabled
KV Out of Tolerance
Low Output Current
(Not Used)
WORD/
BIT
MODULE OUTPUT
0
1/00
1/01
1/02
1/03
1/04
1/05-07
Not Used
MicroPak
MicroPak
MicroPak
MicroPak
MicroPak
Not Used
------
High Voltage On
Command
High Voltage Reset
Fluid Trigger
Air Trigger
Di/dt Inhibit
------
DISCRETE OUTPUT
CONFIGURATION
* See "Configuration Word Construction" in Appendix 1.
** If no SerAT Modules Installed, next module type moves to this position.
*** See following "Tolerance Word Construction."
Serial Node Adapter/Serial Node Adapter + - Operation