Ransburg – Ransburg Serial Node Adapter LECU4002_78553 User Manual

Page 37

Advertising
background image

If the address 0 motherboard is a 78145-00, hav-

ing a Serial Node Adapter in the leftmost slot,

the procedure is the same. There is simply no

contribution to a configuration word from this slot

(Word 0, bits 12-15 are zero).

If any of the slots are empty, simply enter zero

for that slot.

With MicroPak

When a MicroPak is used, there is no change to

the configuration system. There is no configura-

tion word used for the MicroPak, but MicroPak

switch SW7 must be set at the default, address

1 (positions 1, 2, and 3 ON, position 4 OFF). In

the following example, a MicroPak motherboard

has been added to this combination.

The configuration words are identical to that above.

Note that at least one of the motherboards in this

example must be located in another physical rack.

The above examples show a maximum number

of modules communicating with one Serial Node

Adapter. A more practical system (single bell)

might be:

Serial Node Adapter/Serial Node Adapter + - Operation

Ransburg

33

LN-9238-02.3

Advertising