Cleaning, Wiring diagram, Installation – Reversomatic SA-90S_SA-90SM User Manual

Page 4: Cont.) c) sa-90sl

Advertising
background image

- Disconnect power supply
- Remove fan grille
- Clean grille with warm water and mild detergent (liquid soap). Do not use harsh detergent or
boiling water
- Dry grille with a cloth or towel
- Clean fan blades carefully
- Never allow water to enter into the motor
- Replace fan grille in place

CLEANING

B) Existing Construction

Before cutting a new hole in the existing ceiling:
- Choose best location (next to ceiling joist)
- Make sure the duct work can be installed and has easy access to exterior air outlet
- Wiring can be run to the planned area
- Make sure no existing wiring or other obstruction will interfere with installation
- Follow Installation A

NOTE:
In case of replacing an old unit, check existing duct work and electrical wiring and follow
installation A.

WIRING DIAGRAM:

(cont.)

C) SA-90SL

FAN

MOTOR

CAPACITOR

TO SWITCH

LIGHT UNIT

TO SWITCH

TO NEUTRAL

TO NEUTRAL

TO GROUND

JUNCTION

BOX

BLACK

WHITE

GREEN

FAN HOUSING

Ballast

1

Ballast

2

BLACK

BLACK

WHITE

WHITE

A) Wooden Joist Installation

- Install fan housing between ceiling joists using sufficient length of
screws as shown in Fig. 1 with the fan O/L facing the desired
exhaust duct direction.
- Install fan mounting brackets as shown in Fig. 2 to the fan sides
that are not connected to the joists.
- If the brackets are too short to reach the joist, use bracket
extensions
- Connect the circular duct to the backdraft damper. Secure with
duct tape and make sure there is no air leakage.
- Do not use power supply wires smaller than 14 AWG.
- Always use the metal duct and try to avoid flexible duct

INSTALLATION

Fig. 1

4

visit: www.reversomatic.com

j.tantay 10.07.09

Advertising