Replacing existing thermostat, Features – Robertshaw 9515 User Manual

Page 2

Advertising
background image

Features

• Multi stage heating and cooling control

• Zone system compatible as a master thermostat

• Auxiliary heat

• Fahrenheit/Celsius display option

• Adjustable from 45°F (7°C) to 90°F (32°C)

• Accuracy within ± 1 degree

• Adjustable 1st stage temperature differential: 1°-3°,

2nd stage temperature differential: 2°-6° F

• Automatic heating shutdown if temperature exceeds 90°F (32°C)

• Battery free memory storage

Replacing Existing Thermostat

1. Turn off power to heating and cooling system.

2. Remove cover of old thermostat to expose wires.

Do not disconnect wires (Figure 1).

3. Label wires per Table 1.

Table 1

Old Label

New Label

Description

R, V-VR or VR-R

R

24 VAC, Return

Y, Y1 or M

Y1

1st Stage Cooling
Circuit

O or R

O

Reversing Valve,
(Cooling Mode)

B

B

Reversing Valve
(Heating Mode)

F or G

G

Fan Control Relay

Y2

Y2

2nd Stage Cooling
Circuit

W2 or W-U

W2

2nd Stage Heating
Control

C, X or B

C

24 VAC, Transformer
Common Side

W1 or W

W1

1st Stage Heating
Circuit

*NOTE: T

HIS THERMOSTAT REQUIRES A

24V

COMMON WIRE FOR PROPER OPERATION

.

2