Operating instructions, Warning, Evacuating the a/c system – Robinair 177002K Recovery, Recycling, Recharging Unit User Manual

Page 16: The control panel during evacuation, 2001 robinair, spx corporation, R-134a, I0 0, 0r r, Vacuum, Vac-charge

Advertising
background image

© 2001 Robinair, SPX Corporation

14

RECOVER

RECOVER

VACUUM

VACUUM

CLOSED

CLOSED

RECOVER

RECOVER

VACUUM

VACUUM

CLOSED

CLOSED

VAC-CHARGE

VAC-CHARGE

ENTER

ENTER

R-134A

R-134A

R-134A

R-134A

in Hg

in Hg
VAC

VAC

psi

psi

bar

bar

kPa

kPa

psi

psi

bar

bar
kPa

kPa

RECOVER

RECOVER

CHARGE

CHARGE

OIL INJECT

OIL INJECT

0

0

0

0

3

3

0

0

0

0

5

5

4

4

0

0

0

0

2

2

0

0

0

0

0

0

5

5

0

0

0

0

4

4

3

3

5

5

4

4

7

7

CLEAR

CLEAR

MENU

MENU

8

8

0

0

1

1

5

5

2

2

VACUUM

VACUUM

START

START

I

I

0

0

F1

F1

9

9

6

6

3

3

CHARGE

CHARGE

STOP

STOP

0

0

0

0

2

2

0

0

0

0

0

0

1

1

0

0

3

3

0

0

2

2

1

1

0

0

0

0

4

4

7

7

5

5

0

0

2

2

3

3

0

0

R

R

5

5

3

3

0

0

0

0

4

4

0

0

0

0

2

2

8

8

3

3

2

2

1

1

0

0

3

3

0

0

4

4

0

0

4

4

0

0

8

8

2

2

1

1

0

0

D

D

R

R

A

A

T

T

E

E

0

0

8

8

0

0

1

1

1

1

0

0

0

0

0

0

0

0

8

8

7

7

6

6

0

0

0

0

0

0

5

5

6

6

0

0

7

7

0

0

0

0

1

1

0

0

0

0

9

9

0

0

1

1

0

0

5

5

5

5

1

1

0

0

0

0

1

1

5

5

0

0

0

0

0

0

0

0

0

0

0

0

5

5

0

0

0

0

1

1

0

0

5

5

0

0

2

2

1

1

0

0

5

5

0

0

0

0

1

1

3

3

0

0

0

0

5

5

0

0

4

4

0

0

0

0

2

2

0

0

5

5

0

0

2

2

0

0

3

3

0

0

6

6

0

0

2

2

5

5

0

0

HIGH

HIGH

Operating Instructions

EVACUATING THE A/C SYSTEM

WARNING

Wear safety goggles when working with refrigerant. Use only
authorized refillable refrigerant tanks. Read and follow all warnings
at the beginning of this manual before operating the unit. In addition
to the number keys, the keypad contains special keys that
accomplish specific operating functions.

NOTE:

If any oil was drained from the system during recovery, DO NOT use the VAC-

CHARGE feature. The oil must be replenished into the A/C system, which is not
possible when the VAC-CHARGE function is used.

If the vacuum pump has been run more than 10 hours since the last oil change,

the display reads: VACUUM OIL TIME XX:XX. Press the

STOP

key to change

the vacuum pump oil, or press the

START

key to continue. Instructions for

changing the vacuum pump oil are located in the maintenance section of this
manual. NOTE: Vacuum pump oil should be changed after every 10 hours of
use to maintain maximum performance and endurance levels.

If the system being evacuated contains a pressure over 25 psi at any point during

the evacuation, the display reads PRESSURE EXISTS. This message indicates
that the A/C system contains refrigerant; press any key to continue. Press the

RECOVERY

key to recover any refrigerant in the system (See RECOVERING

REFRIGERANT, page 12). After recovery is complete, return to evacuating the
A/C system.

VAC-CHARGE

1. Press the

VAC-CHARGE

key to select the VAC-CHARGE feature.

2. Ensure the service hoses are connected and both panel valves are in the

VACUUM/ RECOVER position. Press

START.

IMPORTANT!

Evacuate the
system for at
least 15
minutes to
ensure
adequate
moisture and
contaminant
removal
.

IMPORTANT!

If the vacuum
pump has run
for 10 or more
hours without
an oil change,
the message
VACUUM OIL
TIME XX:XX
appears on the
display.
Change the
pump oil
following the
procedures in
the
MAINTENANCE
INSTRUCTIONS.

Vacuum

INST0929

The Control Panel

During Evacuation

Vac-Charge

Advertising
This manual is related to the following products: