21

34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit

Maintenance Instructions

IMPORTANT!

Inspect the unit
periodically for
leaks. The
manufacturer
does not
reimburse for
lost refrigerant.

CHECKING FOR LEAKS

Every three months, or as specified by local or state laws, you should check the
unit for leaks.

1. Turn off the

MAIN POWER

switch, and disconnect the power cord from the

outlet.

2. Open the rear door. Remove the top cover and front panel.

3. Use a leak detector to probe all connections for refrigerant leaks. Tighten

fittings if a leak is indicated.

4. Reassemble the body panels and close the rear door.

Diagram of Vacuum Pump

1. Oil Filler Tube
2. Pump Exhaust
3. Oil Fill Port
4. Sight Glass
5. Oil Drain Fitting
6. Inlet

4

OPEN

OPEN

CLOSE

CLOSE

1

2

6

3

5

Advertising