AQD3 Series Installation continued

AQD3 Series Instructions: Doc.# 500-33000 Rev A

Page 10 of 15

PDB-4F / PDB-8F

Multi Output

Low Voltage Power Distribution Modules

Life Time Warranty

Features/Specifications:

Converts a single AC or DC (12 or 24v) Input to 4 or 8 protected

outputs with fuses or circuit breakers

1500 Watt surge protection on PDB-8F Input rated 22 Amps @ 32

volts AC or DC

All PTC circuit breaker ratings are holding current at 130oF per UL

Standards

Main Power Green/Red LED Indicates AC, DC or Reversed DC Input on

PDB-8 and PDB-9

Each output has a green status LED indictor

Current Draw is 6ma max per LED

Main Fuse / Power Pull is standard ATO Automotive size on PDB-8

ON / OFF Power Switch on PDB-4F

Circuit Breaker Models with Rated Output 1.42 Amps or below are

Power Limited

PDB-8F & PDB-8C are

As configured in UL listed

products.

PDB-4F, PDB-4C, PDF-8F, & PDB-8C are UL listed Sub

Assemblies As configured in UL listed products
suitable for Access Control and Burglar alarm systems

All Input Terminal blocks and output terminal blocks on the PDB-8F module

are rated 40A with a wire range of 10 – 18AWG

Output Terminal blocks on the PDB-4F are rated 10A with wire range 16-

30AWG

Size: PDB 4F 3.75”H x 2.22”W x 1”D Mounting: 3.41”H x 1.87”W

Size: PDB-8F 3.87”H x 4.84”W x 1”D Mounting: 3.41”H x 4.49”W
Quality Manufactured in the USA

Custom Order details NOT UL LISTED






PDB-4F-FFF

4 Fused Outputs with power switch and status
LED’s.

PDB-4C-CCC

4 PTC Circuit Breaker Outputs with power switch
and status LED’s

PDB-8F-MMM-
FFF

8 Fused Outputs with ATO Main/power pull fuse,
status LED’s and 1500 watt surge protector.

PDB-8C-MMM-
CCC

8 PTC Circuit Breaker Outputs with ATO
Main/power pull fuse, status LED’s and 1500 watt
surge protector.

PDB-9F-MMM-
FFF

9 Fused Outputs with ATO Main/power pull fuse and
status LED’s.

PDB-9C-MMM-
CCC

9 PTC Circuit Breaker Outputs with ATO
Main/power pull fuse and status LED’s

FFF
Fuse Options

FFF = Fuse Rating in Amps (x.xx) standard 3agc
Size:
(050 = 500ma); (100 = 1A); (200 = 2A);
(300 = 3A); (400 = 4A); (500 = 5A)

CCC
Circuit Breaker
options

CCC = PTC part number equaling the holding
current in Amps at UL rating 50C:
(090 = .7A); (135 = 1.04A); (160 = 1.23A);
(185 = 1.42A); (250 = 1.93A); (400 = 3.08A);
(500 = 3.85A); (600 = 4.62A)

MMM
Main Fuse options

MMM = Main Fuse Rating in Amps (xx.x) – Standard
Automotive ATO Size:
(050 = 5A); (075 = 7.5A); (100 = 10A);
(150 = 15A); (200 = 20A); (250 = 25A)

PDB-4F

PDB-4C

PDB-8F

PDB-8C



UL 294 – Access
Control System Unit
UL 603 – Power
Supplies for Use with
Burglar-Alarm
Systems
ULC S318-96 – Power
supplies for Burglar
Alarm Systems
ULC S533-02 –
Standard for Egress
Door Securing and
Releasing Devices

PDB-9F

PDB-9C

Below

NOT EVALUATED

BY UL