AQD3 Series Installation continued

AQD3 Series Instructions: Doc.# 500-33000 Rev A

Page 3 of 15

AQD3 Supervised added features:

DC Output Electronic Power Limited ...................... Yes
This feature limits the output current to a maximum
peak of 6Amps to comply with UL Power Limiting
requirement.
AC Status Output Relay: 3P Terminal block
AC Fail form “C” contacts rating .................... 2A, 24Vdc

Three position AC fail terminal block marked “NO, C, NC” are
shown in the Normal, energized, “AC ON” condition.

Using these relay contacts as a switch with a proper DC
power source the AC power loss can be locally annunciated
as required with Amber or Red Led indicator or sounding
device. The contacts my also be used to annunciate, AC
failure to a Listed Burglar Alarm or Access Control panel.

Trouble / LTW Limited Time Warning of stand by
batteries 95% of Battery has been depleted

Output, 2 position header .1” spacing (+&-) (-) sinks 3ma
The LTW circuit “MUST” be connected either for local
or remote annunciation with an Amber or Red LED to
indicate DC Trouble or you may annunciate the LTW
by connecting the (-) negative open collector output to
an appropriate input of a UL Listed Burglar Alarm or
Access control panel. When DC Power is normal, the
(-) negative output is an open circuit with the LED OFF.
When the DC output voltage drops to a point where the
standby battery has been 95% depleted, the LTW (-)
turns the LED ON to indicate trouble. The LED
remains ON after the Stand by battery has been
electrically removed from the DC Output.
The Figure LTW Led below shows the hook up on an
LED. The following parts (not provided) will be needed
to connect the LED to the LTW Header Output.
1 connector housing .1” spacing with ramp Molex
P/N: 22-01-2021
2 Female connecters for housing Molex
P/N: 08-50-0113
Wire to connect LED connectors are rated for 22-
30AWG

Figure LTW Led

Low Battery Disconnect (Battery cut-off)
12v/24v ........................................ 9.8Vdc/Vdc/19.6Vdc
Physical AQD3
For Indoor Use Only
Module Dimensions ................... 4.84”Lx3.73”Wx2.25”H

Height includes required 5/8” #6 FF Hex aluminum standoffs,
not provided with module only.

Mounting Holes Center to Center ........ 4.50”W x 3.41”H

AQD3 Dimensions…… ........................ 14”W x 9”H x 3.5”
AQD3 Weight ........................................................ 6.7Lbs
Standards
RoHS Compliant Lead Free – Not evaluated by UL
UL 603 Power Supplies for Use with Burglar Alarm
Systems.
UL 294 Access Control System Units.
ULC-S318-96 Power Supplies for Use with Burglar
Alarm Systems
The units are not to be employed as a power source
for Local Audible Alarm Sounding Devices or for Off
Premise Alarm Transmitters/Communicators, or
Household Burglar Alarm Units.