3.3. INPUT LINENT & POWER FACTOR

3.4. EFFICIENCY

3.4.1 General

Under the load conditions defined in Table 1 and Table 2. The loading condition for testing
efficiency shown in Table 1 represents a fully loaded system. a ~ 50-60% (typical) loaded
system.and a ~ 20-30% (light) loaded system.

Minimum Efficiency for test purposes are considered to be within ±1.0% of nominal.

Table 1. Loading Table for Efficiency Measurement

Table 2. Minimum Efficiency Vs Load

Loading

Voltage

Full

load

Typical

load

Light

load

Required Minimum Efficiency

115V

80%

81%

80%

Required Minimum Efficiency

230V

80%

81%

80%

300W (loading shown in Amps)

Loading +12V1 +12V2

+5V

+3.3V

-12V +5Vsb

(At Full load)

AC input

115V

< 3.5Amps – rms

< 2.0Amps – rms

> 0.95

> 0.9

>0.8

>0.75

230V

Input line current

P.F.@ Full Load

P.F.@ Pin=75W

Full
Typical
Light

7.56
3.78
1.51

8.64
4.32
1.73

11.5
5.75
2.3

10.46
5.23
2.09

0.37
0.18
0.07

1.84
0.92
0.37