St50gf-st42gf--mauual-v1-p1~p2, Specification – SilverStone ST42GF Manual User Manual

Page 2

Advertising
background image

ST50GF / ST42GF

SPECIFICATION

SilverStone GEMINI

SST-ST50GF

SST-ST42GF

Mini Redundant Switching Power Supply

With Active PFC

500W+500W

420W+420W

1. Input Requirements

1-1. Input Voltage

The power supply shall be operated at universal input voltage defined in the following table.

1-2. Frequency

The input frequency range is from 47Hz to 63Hz.

1-3. Inrush Current

The max inrush current is 100A for 115/230VAC.

1-3-1. Cold Start

1-3-2. Warm Start

01

lnput Voltage

NOM

MIN

MAX

264

Voltage

90

100-240

Conditions

Limits

115/230VAC, full load.
25 C ambient.

No component over stress or
damage should occur to the
power supply.
Input fuse shall not blow.

O

Conditions

Limits

Turn off at 132/264VAC full
load for 1 sec then turn on at
the peak of the input voltage
cycle at 25 Cambient.

No component over stress or
damage should occur to the
power supply.
Input fuse shall not blow.

O

1-4. AC Input Current

SST-ST50GF SST-ST42GF

1-5. Efficiency

The power supply efficiency typical> 82% at 115V

,full load.

1-6.Leakage current

3.5mA max, At 240Vac/60Hz.

2. Output Requirements

2-1. Output Regulations

Note:

1. The above voltage range should also include ripple and noise.

2. The output voltage should be measured at the terminals of output connector.

02

AC Input

115V

230V

8

4

AMPS

AMPS

MAX

Units

AC Input

115V

230V

7

3

AMPS

AMPS

MAX

Units

Output
Voltage

+5V

+12V

-12V

+3.3V

+5Vsb

MIN

+4.75

+11.40

-10.80

+3.135

+4.75

Nominal

+5.00

+12.00

-12.00

+3.30

+5.00

MAX

+5.25

+12.60

-13.20

+3.465

+5.25

Units

Volts

Volts

Volts

Volts

Volts

Range

5%

5%

10%

5%

5%

+

-

+

-

+

-

+

-

+

-

Advertising