ST50GF / ST42GF

3-2. Short Circuit Protection
A short circuit placed to ground shall cause no damage or power supply shall be shutdown.
(The contact resistance is 0.05 ohm when the outputs short circuit.)

3-3. Protection Reset
When the power supply latches into shutdown condition due to a fault on an +5V,+3.3V,+12V,
output (OVP, UVP,OCP), the protection shall reset after the fault has been removed, use remote
on/off control or recycle the AC power again for a typical of 5 seconds.

3-4. Over Shoot
Any output overshoot at turn on shall be less than 15% of the nominal output value (with
resistive load) as described in sec. 2.1.

3-5. Over Power Protection
At 115/230Vac input the power supply will shut down all DC output within max 150% of full
load.

3-6. Over Current Protection

Max.160% for +5V,+12V,+3.3V dc output rail.

4. Environment

4-1. Operation/Storage Temperature Range

Operation : 0 C to 50 C(nominal input)

Storage : -20 C to 60 C

FIGURE 3. Operation/Storage Temperature Range

4-2. Humidity (none condensing)
Operation: 20% to 90% RH (nominal input)
Storage : 5% to 95% RH

5. Safety

5-1. UL 60950-1
5-2. BSMI (CNS14336:94)
5-3. TUV EN 60950-1:2006+A11
5-4. CB

07

O

O

O

O

08

6. EMI Requirements

6-1.CE

6-2. BSMI (CNS13438:95)

6-3. FCC part 15 sub part J class B at system load

6-4. CISPR 22 CLASS B

7. Dielectric Voltage Withstand (HI-POT)

The power supply shall withstand for 3 seconds without breakdown the application of an
1800Vac-supply voltage applied between both input line and chassis (10mA AC Cutoff
current). Isolating transformers shall similarly withstand 4242Vdc applied between both
primary and secondary windings for a minimum of one minute.

8. PFC

Active Power Factor Correction, complies with EN 61000-3-2: 1995+A1+A2:1998, Class D.

9. Electrostatic Discharge (ESD)

Comply with IEC 61000-4-2.

10. EFT/ Burst

Comply with IEC 61000-4-4.

11. Surge

Comply with IEC 61000-4-5.

12. Burn-In

Applying 115 Vac 10 % or 230 Vac 10% input voltage and maximum load (80%) for this
product in 40 5 C chamber.

13. M.T.B.F.

The power supply shall have a minimum mean time between failure greater than 100,000
hours Minimum (Without Cooling Fan) at continuous operation of 100% load and an ambient
temperature of 25 C.