3.

Whilst holding the locator in
the forward position, insert
the crimp contact into the
correct locator nest. The wire
size is marked on the crimp
die, above each location.

4.

Release the locator button, allowing
the crimp contact to move back
between the crimping jaws.

5.

Close the handle, until the second
ratchet position engages.

6.

Load the stripped wire
through the terminal, and
against the wire stop inside
the tool.

7.

Whilst holding the wire against the wire stop,
complete the crimp by squeezing the tool handles
together through the rest of the ratchet clicks –
another 3, to make 5 in total. The handles should
then be free to open. Remove the crimped wire.

CRIMP INSPECTION

Crimp joints should be checked for:

Correctness of form and location of crimp.

Freedom of fracture and rough edges.

Adequate insertion of all conductor strands in the crimp barrel.

Absence of damage to the conductor or the insulation.