4.8 Pause


Example of use in operation) The actuator is paused during movement.

Method) Use the pause input.

RCS controller

















































P

L

C

[5] [2]



[1]



[8] [6]







[11]



[10] [3]

PIO

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

Pause

Reset

Servo ON

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Position complete

Home return completion


Zone

Alarm

Emergency stop

Moving

Category

Input
















Output


Reference flow

Select/enter a desired command position.

[1]

[2]








[3]

[4]

[5]

[6]



[7]

[8]

[9]

[10]

[11]

[12]


Start input ON

Completed position OFF

Position complete output OFF

Moving output ON

Start input OFF

Moving output OFF

Movement to the selected position
completes.

Position complete output ON

Completed position is output.

Movement to the selected position starts.

Pause input OFF (Actuator
decelerates to a stop.)

Pause input ON (Movement starts.)

[12] [9] [7] [4]

Moving output OFF

Moving output ON