IAI America RCAW User Manual

Page 69

Advertising
background image

4. Maintenance

63

4.5.4 Replacing the Belt of the Motor Reversing Type: RA3R/RA4R Types

[Items Required for Replacement]

y

Replacement belt

RA3R······60S2M124R Rubber, cleanroom type (Bando Chemical Industries) 6 mm wide

RA4R······60S2M152R Rubber, cleanroom type (Bando Chemical Industries) 6 mm wide

y

Allen wrenches

y

Tension gauge (capable of tensioning to 7 kgf or greater)

y

Strong string, looped (or long tie-band)

y

Scale

y

Oil-based marker pen

y

PC or teaching pendant

[Overview of Replacement]

1) Move the rod to a position where Z phase turns on (home position) (2 mm from the mechanical end).

In this position, loosen the motor-unit affixing bolts and replace the belt.

2) Restore the home position.

Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust

the belt to the specified tension.

3) Perform homing using a PC or teaching pendant and check for deviation from the initial home

position.

If there is a deviation, adjust the home offset if you are using an ACON controller. If you are using an

ASEL controller, adjust the home preset.

Home position

Z phase ON

position

Mechanical end

Approx. 2 mm

The countermark on the motor

aligns with this position.

Set by the home offset parameter (ACON) or home

preset parameter (ASEL). (The above value indicates

the factory setting.)

1 mm

Advertising