IAI America SSPA User Manual

Page 52

Advertising
background image

7. Connecting the Controller

44

x

When fixing the cable, provide a moderate slack and do not tension it too tight.

x

Separate the I/O and communication lines from the power and drive lines. Do not wire them together in the

same duct.

Follow the instructions below when using a cable track.

x

If there is an indication to the cable for the space factor in a cable track, refer to the wiring instruction given by

the supplier when storing the cable in the cable track.

x

Avoid the cables to get twined or twisted in the cable track, and also to have the cables move freely and do not

tie them up. (Avoid tension being applied when the cables are bent.)

Do not pile up cables. It may cause faster abrasion of the sheaths or cable breakage.

Warning:

z

Always turn off the controller power before connecting/disconnecting cables. If cables are connected/

disconnected while the power is still supplied, the actuator may malfunction and serious injury or equipment

damage may occur.

z

Loose connectors may cause the actuator to malfunction and create a dangerous situation.

Be sure to confirm that all connectors are securely connected.

Power line

I/O lines (flat cable)

Duct

Do not use a spiral tube where

the cable flexes frequently.

Advertising
This manual is related to the following products: