6. Precautions for Use

Warning

(6) Press the emergency-stop switch.

(7) When performing an absolute reset of arm 1, set an adjustment jig (pin) on arm 1 to fix the arm in the

reference position. In this case, arm 2 may be moved. When performing an absolute reset of arm 2,
set an adjustment jig (pin) on arm 2 to fix the arm in the reference position. In this case, arm 1 may be
moved.
x Set the jig after confirming that the emergency-stop switch is pressed.
x Set the jig after adjusting the arm to the reference position, using the positioning mark label as a

guide.

x Arm 1 has a cover (not arm 2), which is fixed with setscrews. Remove the setscrews and detach

the cover before setting the jig.

x It is recommended that an adjustment jig be used to perform an absolute reset. With arm 1 or 2,

however, rotation data can be reset as long as a positioning accuracy of “center of positioning mark
label

r1 graduation” is ensured.

z Always press the emergency-stop switch before setting an adjustment jig. Failure to do so may

cause the robot to malfunction and result in a serious accident.

Positioning mark
label for arm 1

Positioning mark
label for arm 1

Positioning
mark label for
arm 2

Adjust arm 1 or 2 to a
position within ± 1
graduation of the center.

Reference position drawing

Arm 1

Arm 2

Advertising