Specifications – Aube Technologies TH303 User Manual

Page 21

Advertising
background image

TH303

19

- Supply: 120/240 VAC, 60 Hz
- Minimum load:

0.83 A (resistive only)
200 W @ 240 VAC
100 W @ 120 VAC

- Maximum load:

10.4 A (resistive only)
2500 W @ 240 VAC
1250 W @ 120 VAC

- Setpoint range: 5°C to 30°C (41°F to 85°F)
- Display range: 0°C to 70°C (32°F to 99°F)
- Setpoint/display resolution: ±0.5°C (±1°F)
- Operation: 0°C to 50°C (32°F to 120°F)
- Storage: -20°C to 50°C (-4°F to 120°F)
- Permanent memory:You do not need to adjust the temperature settings or the thermostat’s

configurations following a power outage. However, you might need to
set the thermostat’s clock and date if the outage lasts more than 4
hours.

Specifications

400-303-000-C EF (4.5 x 3) ENG.fm Page 19 Friday, June 19, 2009 9:28 AM