6 zone output signal – IAI America PCON-CY User Manual

Page 79

Advertising
background image

69

5. Operation Using I/O Signals

5.3.6

Zone Output Signal

This signal remains ON while the actuator is inside the zone set in the position table.
The zone output signal can be set only at a single point, but a different zone can be set for the move command corresponding
to each target position (rear end, front end, or intermediate point).

Use the zone output signal in the following situations.
[1] Set an interlock signal to prevent contact with peripheral equipment.
[2] Set a trigger signal for peripheral equipment to reduce the tact time.
[3] Detect missed work during push-motion operation.
[4] Determine the end point when positioning to a series of aligned works via constant pitch feed.

(Note) In constant pitch feed, the “Position” field indicates a relative distance. However, the zone is still set as an

absolute coordinate from the home.

[Setting example]

Rear end

Front end

Intermediate point

Position

[mm]

Zone +

[mm]

Zone –

[mm]

Comment

Zone output signal

Home

Rear end

Move command to the rear end

Move command to the front end

Move command to the intermediate point

+ side limit

Front end

Intermediate

point

Zone output signal

Zone output signal