4-3-53. SCARA

Relative-Coordinate Specification Movement (2D5H)

Function: Move to the relative coordinates specified with respect to the current position (SCARA).

Data name

Data range (value)

Data size

[bytes]

Cumulative

bytes [bytes]

Endian Sign

extension

Unit Description

Remarks

Big Little

Yes No

Command

Header '!'

1

1

Station 'XX(h)'

2

3

Message ID

'2D5(h)'

3

6

Axis pattern

'XX(h)'

2

8

For the X-SEL-PX/QX/RX/SX series, simultaneous specification of
SCARA and direct-acting axes is prohibited (direct-acting axes can be
specified).

Acceleration 'XXXX(h)'

4

12

% or 0.01 G

The parameter setting becomes effective if 0.
* Unit: Movement control = PTP: [%] / Movement control = CP: [0.01 G]

Deceleration 'XXXX(h)'

4

16

% or 0.01 G

The parameter setting becomes effective if 0.
* Unit: Movement control = PTP: [%] / Movement control = CP: [0.01 G]

Speed 'XXXX(h)'

4

20

% or mm/sec

The parameter setting becomes effective if 0. (Safety limit applies
depending on the mode.)
* Unit: Movement control = PTP: [%] / Movement control = CP: [mm/sec]

Positioning operation
type

'XX(h)' 2 22

(Invalid for non-SCARA axes)
Bits 5 to 7 (Reserved for system use)
Bits 3, 4 (PTP target arm system specification type (Always move current
arm system if CP)): 0 = Current arm system (Movement of opposite arm
system prohibited if unfeasible) / 1 = Current arm system (Movement of
opposite arm system permitted if unfeasible) / 2 = Right arm system
(Movement of opposite arm system prohibited if unfeasible) / 3 = Left arm
system (Movement of opposite arm system permitted if unfeasible)
Bits 1, 2 (Movement coordinate system): 0 = Reserved for system use / 1
= Selected work coordinate system / 2, 3 = Reserved for system use
Bit 0 (Movement control): 0 = PTP / 1 = CP

Relative coordinate
data (*1)

'XXXXXXXX(h)' 8

30 

0.001

mm

Remaining relative
coordinate data

Data indicated by *1

for the number of

remaining axes

MAX

56

MAX

86

0.001 mm

(R-axis:

0.001 deg)

Data indicated by *1 x Number of remaining effective axes = 8 bytes x
(Max 8 – 1) axes = Max 56 bytes

SC 'XX(h)'

2

MAX

88

CR 0Dh

1

MAX

89

LF 0Ah

1

MAX

90

Norm

al

respon

se

Header '#'

1

1

Station 'XX(h)'

2

3

Message ID

'2D5(h)'

3

6

SC 'XX(h)'

2

8

CR 0Dh

1

9

LF 0Ah

1

10

Error

respon

se

Error response format

Refer to the error

response format.

10 10

(Note 1)

Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.

(Note 2)

Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is added before the closing
quotation mark.