1 gw_ctl_11 – IAI America RCM-GW-PR User Manual

Page 113

Advertising
background image



107

PfofiBus Gateway

8.1 GW_CTL_11















Explanation; This is a function to access Gateway control/status words.

Before calling other function block/function, communication between the Gateway and
the controller must be started using this function. Axis configuration must also be
defined in the ProfiBus module.

Parameters;

I/O

Parameter

name

Data

type

Explanation

Input MON

BOOL Start

Gateway-controller

communication.

CFG

WORD

Specify an axis to be actually configured using a bit
pattern (bit 0 = Axis 0, bit 15 = Axis 15).

NPS

INT

Number of axes used in the POS-number
specification movement mode. Axis numbers are
assigned from 0 based on this value, and the direct
numerical specification mode becomes effective for all
remaining areas. *1

PPS

INT

PIO pattern number in the POS-number specification
movement mode *1

LADDR

WORD

Output Gateway head I/O addresses for output

Output GW_STS

WORD

Gateway status word 0 is output.

LNKS

WORD

Gateway status word 1 is output.

*1 This setting is effective only when the mode setting switch is set to 0x1, 0x5 and 0x9.

Modbus communication start

Axis configuration definition word

Number of POS mode axes

POS-mode PIO pattern number

Gateway head address

Gateway status

Axis link status