Caution – IAI America RCM-GW-PR User Manual

Page 93

Advertising
background image



87

PfofiBus Gateway

(2) Home return operation

The controller unit uses an incremental position detector (encoder), which means that once the power
is cut off, the mechanical coordinates will be lost.
Accordingly, home return must be performed after the power is turned on to establish the mechanical
coordinates.
To perform home return operation, input the home return command (HOME) signal.
For your information, home return operation is not required if the simple absolute R unit is connected
to the controller unit to convert the axes into absolute axes.


Operation timings

PLC process 1: The home return command (HOME) signal turns “1” (ON) when the start button is

pressed.

Operation:

[1] The actuator starts moving toward the mechanical end on the home side.
[2] After contacting the mechanical end, the actuator reverses its direction and then

stops at the home position

→ The home return complete (HEND) signal turns “1”

(ON).

PLC process 2: The home return command (HOME) signal is turned “0” (OFF) after confirmation of the

HEND signal turning “1” (ON).

PLC process 3: The actuator starts continuous operation.
























Caution

Pay attention to the following points when performing home return:
[1] Confirm that no obstacle exists in the direction of home return.
[2] Should an obstacle be found in the direction of home return, tentatively move the actuator in the

direction opposite home and remove the obstacle.

[3] Turning the HOME signal “1” (ON) turns the PEND signal “0” (OFF) and MOVE signal “1” (ON).
Turn the HOME signal “0” (OFF) again after confirming that the HEND signal has turned “1” (ON) while
the HOME signal is still “1” (ON).

Home return command


Home return complete


Positioning complete



Moving



Actuator movement

[1] [2]

1 msec or less

Po

w

e

r in

p

u

t

po

sition

M

e

c

h

an

ic

al

e

n

d

H

o

m

e

po

s

iti

on