9

Setup is separated into many different categories ranging from "Interface" to "Cloning". The following is a list of function keys and
the setup category for which they apply:

Key

Category

Options

F1

Interface

Transmit Speed
Keyboard Country
CTRL/Special Char Delay
Send Numerics As
Setup Mode Lockout
Output Mode
Serial Baud Rate
Serial Data Bits
Serial Parity
Serial Duplex
Serial Data Format
Inverted Serial Output
Serial Intercharacter Delay
Serial Caps Lock
Serial Num Lock

F2

Decoders/Scanner

Decoders On/Off
Code 39
Code 128
Interleaved 2 of 5
Codabar
Other

F3

Editing

Edit #1 - Edit #5

F4

Macros/Special Keys

Macro #1 - Macro #5
Keys

F5

Strings

String #1 - String #5

F6

Reserved

F7

Buzzer/LED

Power Up Beep
Good Read Beep Tone
Beep Duration
No Read LED Delay
LED Power Save Mode

F8

Status/Diagnostics

Firmware Version and Release Date
Keyboard Information
Show Scan Codes

F9

Cloning

Lockout Cloned Reader Setup Mode
Press ENTER To Begin Cloning

F10

Reset All Defaults

Reset All Defaults?


For those categories which have more than one option, the UP and DOWN arrow and ENTER keys are used to move from one
option to the next. In addition to the UP and DOWN arrow keys, the CTRL UP and CTRL DOWN arrow keys are used to move to
the bottom and the top of the list. The following is a list of all special editing keys and a description of their function:

Key

Description

Left Arrow, Right Arrow Toggles through the settings for the current option.
Up & Down Arrow

Moves from one option to the previous or next within the category or group.

CTRL Up & Down Arrow Moves to the top or bottom of the category or group.
Home & End

Moves to the beginning or end of an input field.

ALT Backspace

Toggles the output mode during configuration, between destructive backspace and
non-destructive backspace. Defaults to non-destructive backspace.

CTRL + Keypad

Increases transmit speed during setup.

CTRL - Keypad

Decreases transmit speed during setup.

CTRL F7

Test the current Beep Tone and Beep Duration

CTRL F10

Resets the current option to the default setting.

SHIFT F10

If you are in a category with groups (F2-F5), SHIFT F10 resets the current group. If
you are in a category without groups (F1, F7-F10), SHIFT F10 resets the entire
category.

ALT F10

Resets all options in current category to default settings.

CTRL Escape

Exit configuration, saving changes (Permanent).

ALT Escape

Exit configuration, without saving changes.





Note: If you experience some character loss during setup, you may press the CTRL-(Keypad Minus) key to slow character
transmission. To speed up character transmission, press the CTRL-(Keypad Plus) key.





Note: After 5 minutes of inactivity (no key presses) the decoder will exit setup mode and save all changes.