Correct alignment procedure – IDEC SG2 Type 2 Hand & Body User Manual

Page 5

Advertising
background image

For Emitter:

Function

Status

Meaning

LED

DIGIT

TEST
(green ON)

Light curtain being tested, the OSSD status
on the receiver shall be OFF

Emission
(rated range)
(green ON
yellow ON)

Light curtain working and in normal
operating conditions



Normal
operation

Emission
(reduced range)
(green ON
yellow ON)

Light curtain working in normal operating
conditions



Function

Type

Check and repair

LED

DIGIT

Internal error
(green ON)

Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR

Optical error
(green ON)

Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR

Error status

No power supply
(LEDs OFF)

Check connections and input correct value.
If the failure continues contact
DATASENSOR
















6

Receiver

Emitter

Signals are clearly identified through symbols allowing immediate reading, independent of bars directions.
A short description of the signalling LEDs is necessary to avoid misunderstandings.

Two yellow LEDs (

LAST,

SYNC) on SG2-E receiver, facilitates the alignment procedure.

During standard operation, the LEDs indicate the safety light curtain status, as shown in the table.

Correct alignment procedure

The light curtain alignment can be effected only after having completed the mechanical installation and the
electrical connections. The following procedure has to be followed:

NOTE: SG2-E is equipped with a system which informs the user on the alignment obtained.
The alignment function can be activated when powering the device, by keeping the normally open
RESET/RESTART contact closed for at least 0.5 seconds.

Display

LED

NORMAL

OP.

LED

SAFE

(BREAK)

LED

yellow

SYNC

LED

yellow

LAST

Condition

Alignment

Status

ON

Sync NOK
Last NOK

OFF

ON

Sync OK
Last NOK

OFF ON

OFF OFF

Sync OK
Last OK

Middle optics NOK

NO align.

ON OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

0 and 25%

MINIMUM

align.

ON OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

25 and 50%

ON

OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

50 and 75%

ON

OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

75 and 100%

MAXIMUM

align.



3

Last optics (LAST)

First optics (SYNC) =
synchronisation optics

NORMAL

OP.

NORMAL

OP.

SAFE(BREAK)

LAST

SYNC

ON