4.1.2. Trunk Group

In this example, Trunk Group 6 is associated with Signaling Group 6, and includes trunk
member assignment.

TRUNK GROUP

Group Number: 6

Group Type: isdn

CDR Reports: y

Group Name: Alternate IP600 Test Networ COR: 1

TN: 1

TAC: 106

Direction: two-way

Outgoing Display? y

Carrier Medium: IP

Dial Access? n

Busy Threshold: 99

Night Service:

Queue Length: 0
Service Type: tie

Auth Code? n

TestCall ITC: rest

Far End Test Line No:

TestCall BCC: 4
TRUNK PARAMETERS

Codeset to Send Display: 6

Codeset to Send National IEs: 6

Max Message Size to Send: 260

Charge Advice: none

Supplementary Service Protocol: a

Digit Handling (in/out):enbloc/enbloc

Trunk Hunt: cyclical

QSIG Value-Added? n

Digital Loss Group: 13

Calling Number - Delete:

Insert:

Numbering Format:

Bit Rate: 1200

Synchronization: async

Duplex: full

Disconnect Supervision - In? y

Out? n

Answer Supervision Timeout: 0


Trunk Members
Trunk member port values are initially created by assigning the term “ip” in the Port column.
The system will then assign the T000xx value to the port as shown below.

TRUNK GROUP

Administered Members (min/max):

1/7

GROUP MEMBER ASSIGNMENTS

Total Administered Members:

7

Port

Code Sfx Name

Night

Sig Grp

1: T00049

6

2: T00050

6

3: T00051

6

4: T00052

6

5: T00053

6

6: T00054

6

7: T00055

6