SAVE THESE INSTRUCTIONS

INSTALLATION AND MAINTENANCE

F802GFCI

Thermostat

DANGER

!

!

ELECTRIC SHOCK OR FIRE HAZARD

READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND

SAFETY DATA TO AVOID PROPERTY DAMAGE AND

WARNING

!

!

KING ELECTRIC MFG CO · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH:206 762 0400 · FAX: 206 763 7738 · www.king-electric.com

READ CAREFULLY -

These instructions will help prevent difficulties that might arise during thermostat

installation. Studying the instructions first may save considerable time and money later. Observing the following
procedures will keep installation time to a minimum. Save these instructions for future use.

FUNCTIONS AND FEATURES

Specifications:

Thermostat is suitable for floor heating systems,
Power Supply AC 120/ 240V,50/60Hz
Maximum Load 15A, resistive
Maximum Power 1800W at 120VAC; 3600W at
240VAC
GFI Class A (5 milliamp trip)
Display Range 32℉-99℉(0℃-37℃)
Setting Range 41℉-99℉(5℃-37℃)Accuracy 1
(0.5℃)
Storage Temp. 32℉-120℉(0℃-49℃)
cETLus listing.

Warning: Turn OFF the power at the circuit breaker

before Installing. Installation should be performed by a

qualified electrician.

Refer to thermostat and heater load specifications

before installation of the thermostat to see if it can

handle the amp load. The maximum this thermostat can

run is 3600 Watts at 240 Volts, 1800 Watts at 120 Volts.

Install unit in a grounded metal or plastic wall junction

box, indoors 4 ½’ to 5’ above the floor. Avoid any area

where it can come in contact with external sources of

heat and cold. This includes plumbing pipes, direct

sunlight, a T.V. set, lamps, and drafts from a door or

window, as this may cause inaccurate temperature

readings. The most convenient place is above the light

switch. Not for Outdoor use.

 Dual Voltage (120vac and 240vac)

 7 day programmable settings

 4 Preset Heating Schedules

 Floor and Ambient air sensing

 Blue Backlit Display

 Built-in GFCI and Floor Sensor Included

INSTALLATION INSTRUCTIONS

This Thermostat has been designed for floor heating applications. The built in Ground
Fault Circuit Interrupt (GFCI) provides worry-free operation and includes the floor
sensor. Required for Floor Heat applications

Breaker

Thermostat

Floor

Heater

Cable

Advertising