Congratulations on purchasing a quality, LiftMaster Medium Duty
Commercial Door Operator. Your new operator is capable of
operating up to 12 cycles per hour or 50 cycles per day. It is
equipped with a built in radio receiver that is compatible with our

existing 315 MHz product line as well as a Timer To Close (TTC)
feature that can be enabled when LiftMaster Commercial Protector
System

®

is installed and aligned properly.

DETERMINE THE WIRING TYPE

The functionality of this operator is based on the wiring type. The
operator is shipped from the factory in standard C2 wiring type
(factory default). Some wiring types will require an optional safety
device. Refer to the following descriptions of wiring types,
requirements and programming.

NOTE: 1. The LED on the logic board will blink once when in C2

and twice when in B2.

2. The operator will automatically convert to B2 wiring (option

D) when Monitored Safety Device is installed. If the
Monitored Safety Device is removed, the operator will go
into a Restricted Close mode**. Turn power OFF and ON to
reset wiring type.

** Restricted close mode requires a constant pressure close

command. The operator will begin closing after a 5 second delay
and will continue to close to the close limit switch. The operator
will stop if the pressure to close is released before reaching the
close limit.

To prevent possible SEVERE INJURY or DEATH, install reversing
sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used.
Reversing devices are recommended for ALL installations.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

A

B

C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE
(Factory Default)

C2 WIRING TYPE WITH MONITORED SAFETY DEVICE

• Momentary contact to open and stop with constant

pressure to close.

• Open override that reverses when closing by any opening

device.

• Wiring for safety device to reverse. NOTE: The operator

will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)

• Timer to Close (TTC) feature not available.

• Momentary contact to open and stop with constant

pressure to close.

• Open override that reverses when closing by any opening

device.

• Wiring for safety device to reverse. NOTE: The operator

will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)

• Timer to Close (TTC) feature not available.

Remove any monitored safety devices.
Disconnect then reconnect power to the operator.
Press and hold the LEARN and STOP buttons until the LED goes
out (approximately 3 seconds).

Press and hold the LEARN and CLOSE buttons until the LED goes
out (approximately 3 seconds).

NON-MONITORED SAFETY DEVICE

MONITORED SAFETY DEVICE

Sensing
Edge

Photo Eye

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

Logic Board

Logic Board

Electrical Box

Electrical Box

D14

LED

LEARN

1

2

3

4

5

6

7

STOP

CLOSE

OPEN

D14

LED

LEARN

1

2

3

4

5

6

7

STOP

CLOSE

OPEN

RESET TO C2 WIRING TYPE (Factory Default)

TO PROGRAM

2

B A S I C P R O G R A M M I N G

I N T R O D U C T I O N

Advertising