Remote controls, Timer to close (ttc) – LiftMaster MGJ Medium-Duty Gear-Reduced Jackshaft Operator for Rolling Grilles and Shutters User Manual

Page 4

Advertising
background image

TIMER TO CLOSE (TTC)

Timer to Close feature enables the operator to close from the open
limit after a preset time, adjustable from 5 to 60 seconds.
Requires LiftMaster monitored safety device.

TO PROGRAM
1. Begin with door in fully closed position.
2. Press and release the LEARN button (LED will light).
3. Press and release the TTC button.
4. Every press and release of the STOP button will add 5 seconds

to the Timer to Close. Example: 30 second TTC = 6 presses of
the STOP button.

5. Press and release the TTC button to exit programming mode.
6. The LED will flash once per 5 seconds of timer setting.
The TTC will become active after completion of the next open
cycle.

NOTE: The LED does not indicate that timer is running.

REMOTE CONTROLS

SINGLE BUTTON REMOTE CONTROL
Built in 315 MHz radio receiver permits as many as 20 Security

®

remote controls or dip switch remote controls in any combination.

TO PROGRAM
1. Press and release the LEARN button (LED will light).
2. Press and hold the button on the remote control until the LED

flashes rapidly, then release to complete programming (LED
will go out).

3. Repeat steps 1 and 2 for additional remote controls.

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.

MODE

OPEN

CLOSE

STOP

REVERSE WHILE

TTC

CLOSING

RESET

B2 X

X

X X

B2 X

with

X

(3 button

X

X

X WHEN

TTC

remote)

OPEN

C2

X

X

X

RADIO OPERATION

3-BUTTON REMOTE CONTROL TO OPERATE AS A
WIRELESS 3-BUTTON CONTROL STATION

NOTE: The feature will use 3 of the 20 memory channels in the
operator.

TO PROGRAM
1. Press and hold the LEARN button

(LED will light).

2. Press the desired button on the logic

board (OPEN, CLOSE or STOP). Release both buttons.

3. Press and hold the desired button of the remote control until

LED flashes rapidly, then release.

4. Repeat steps 1 through 3 to program additional buttons.

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

D14

COM INTRLK STOP

LED

OPEN

CLOSE

LEARN

1

MEP1 LMEP2

2

3

4

5

6

7

STOP

CLOSE

OPEN

D14

COM INTRLK STOP

LED

CL

TTC

LEARN

1

LMEP1 LMEP2

2

3

4

5

STOP

CLO

D14

COM INTRLK STOP

LED

OPEN

CLOSE

LEARN

1

MEP1 LMEP2

2

3

4

5

6

7

STOP

CLOSE

OPEN

Logic Board

Logic Board

Timer To Close Button

Logic Board

Electrical Box

Electrical Box

Open

Electrical Box

TO ERASE ALL REMOTE CONTROLS
Press and hold the LEARN button (over 5 seconds) until the
LED goes out. All programmed remote controls will be erased.

CLEAR THE TIMER TO CLOSE (TTC)
1. Press and release the LEARN button (LED will light.)
2. Press and hold the TTC button for 6 seconds.
3. Release the TTC button (LED will go out).
The TTC will no longer be active.

TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button.
TTC will become enabled after the next open command.

OPEN

TO

PRESS

R ING

OPEN

CLOSE

Stop

Close

B A S I C P R O G R A M M I N G

TO VERIFY TIMER TO CLOSE (TTC) SETTING

1. Press and release the LEARN button.
2. Press and release the TTC button.
3. Press and release the TTC button a second time.
4. The LED will flash once per 5 seconds of timer setting.

4