12 SF-16M Matrix Amplifier Installation and Operation Guide

SF-16M CONNECTIONS - Audio Override (Contact Closure)

The SF-16M provides two “Audio Override” contact closure inputs, which allow pushbuttons, partition wall contacts, and

other contact sensors to trigger the system. Audio override provides a convienent method of temporarily switching to an

alternate audio input when a sensor is triggered.

A practical example of this feature is a conference hall with movable partition walls. See Figure 12. When the partition

closes to create individual rooms, a partition wall contact closure (Override 2 in the example) triggers the SF-16M to

switch to a microphone input located in one partion area. When the partition wall opens, the SF-16M returns to its default

audio input. Override 1 can trigger the same behavior or a different behavior.

Figure 12

NOTE: In order for Audio Override to function, all settings must be programmed using the PC configuration software,

available for download on the SF-16M product page.

SF-16M CONNECTIONS - System Trigger (5V-24V AC/DC)

The System Trigger input on the SF-16M allows equipment such as AV receivers or power managment devices to put the

SF-16M in standby when not in use, thereby greatly conserving energy usage.

To enable the System Trigger:

1. Make system trigger connections as illustrated in Figure 13.

2. Power the SF-16M, then apply power to the triggering device.

3. Using the front panel menu (see page 17) or the PC configurator, enable “System Trigger”

Figure 13

1 2

3

4

5

6

7

8

9

10

11 12

13

14

15 16

SPEAKER OUTPUTS (CLASS 2 WIRING)

ETHERNET

USB

SERIAL IN

SERIAL OUT

LINK

SPEED

MAIN IR

IN

MAIN IR

OUT

UNIT ID

DB25 AUDIO INPUT

CONTACT CLOSURE

5V - 24V AC / DC

DB25 AUDIO LOOP OUTPUT

LINE INPUTS

BUS

FlexPort 1

OUT

IN

1 2

IN OUT

SYSTEM

TRIGGER

AUDIO

OVERRIDE

100-120V~ 50-60 Hz

1125W

Replace Fuses Only

with T 10A, 250V

Remplacer Uniquement

avec Fusible T 10A, 250V

Set voltage selector

and install correct

fuses according to

local power supply.

Régler le sélecteur

de tension et

installer les fusibles

corrects selon

l’alimentation locale.

4002715

1

3

5

7

9

11

13

15

A

B

C

D

E

F

G

H

2

4

6

8

10

12

14

16

L

R

ETL LISTED CONFORMS

TO UL STD 60065

CERTIFIED TO CAN/CSA

STD C22.2 NO. 60065

Audio Authority® Corp. • 2048 Mercer Rd. Lexington, KY 40511 USA

800-322-8346 • 859-233-4599 • www.audioauthority.com

Model SF-16M 16-Channel Matrix Amplifier

PDF User Manual

VOLTAGE SELECTOR

FlexPort 2

OUT

IN

1 2

3

4

5

6

7

8

9

10

11 12

13

14

15 16

SPEAKER OUTPUTS (CLASS 2 WIRING)

ETHERNET

USB

SERIAL IN

SERIAL OUT

LINK

SPEED

MAIN IR

IN

MAIN IR

OUT

UNIT ID

DB25 AUDIO INPUT

CONTACT CLOSURE

5V - 24V AC / DC

DB25 AUDIO LOOP OUTPUT

LINE INPUTS

BUS

FlexPort 1

OUT

IN

1 2

IN OUT

SYSTEM

TRIGGER

AUDIO

OVERRIDE

100-120V~ 50-60 Hz

1125W

Replace Fuses Only

with T 10A, 250V

Remplacer Uniquement

avec Fusible T 10A, 250V

Set voltage selector

and install correct

fuses according to

local power supply.

Régler le sélecteur

de tension et

installer les fusibles

corrects selon

l’alimentation locale.

4002715

1

3

5

7

9

11

13

15

A

B

C

D

E

F

G

H

2

4

6

8

10

12

14

16

L

R

ETL LISTED CONFORMS

TO UL STD 60065

CERTIFIED TO CAN/CSA

STD C22.2 NO. 60065

Audio Authority® Corp. • 2048 Mercer Rd. Lexington, KY 40511 USA

800-322-8346 • 859-233-4599 • www.audioauthority.com

Model SF-16M 16-Channel Matrix Amplifier

PDF User Manual

VOLTAGE SELECTOR

FlexPort 2

OUT

IN

PUSHBUTTON

OVERRIDE 1

POWER

MANAGEMENT

DEVICE

TO NEXT SF-16M

SYSTEM TRIGGER INPUT

OVERRIDE 2

PAR

TITION

PARTITION

CONTACT

Advertising