D690-03-00

2 I56-2769-018R

CANDELA SELECTION
Adjust the slide switch on the rear of the product to the desired candela set-
ting in the small window on the front of the unit. All products meet the light
output profiles specified in the appropriate UL Standards. See Figures 1-3.
Use Table 1 to determine the current draw for each candela setting. For K
series products used outdoors at low temperatures, listed candela ratings must
be reduced in accordance with Table 2.
NOTE: SpectrAlert products set at 15 and 15/75 candela automatically work
on either 12V or 24V power supplies. The products are not listed for 12V op-
erating voltages when set to any other candela settings. For 4-Wire products,
total current draw may be determined by adding current draw for the specific
candela selection and the current draw for the specific horn selection use
Table 1 and Table 3.

TABLE 1. STROBE CURRENT DRAW (mA) FOR S, SC, P4 & PC4 SERIES:

Candela

8–17.5 Volts

16–33 Volts

DC

FWR

DC

FWR

Standard Candela Range

15

123

128

66

71

15/75

142

148

77

81

30

NA

NA

94

96

75

NA

NA

158

153

95

NA

NA

181

176

110

NA

NA

202

195

115

NA

NA

210

205

High Candela Range

135

NA

NA

228

207

150

NA

NA

246

220

177

NA

NA

281

251

185

NA

NA

286

258

TABLE 2. CANDELA DERATING:

Listed Candela

Candela rating at –40°F

(K Series Outdoor Applications Only)

15

Do not use below 32°F

15/75

30
75

44

95

70

110

110

115

115

135

135

150

150

177

177

185

185

HORN SELECTION
Turn the rotary switch on the back of the product to the desired setting. For
horn and 4-wire horn/strobe products, the current draw for each setting is
listed in Table 3. For 2-wire horn/strobe products (P2 series), current draws
are listed in Tables 4 and 5. The sound output measurement for each horn
setting is shown in Table 6.
TABLE 3. HORN CURRENT DRAW (mA) FOR H, P4 & PC4 SERIES:

Pos

Sound Pattern

dA Out

8–17.5 Volts

16–33 Volts

DC

FWR

DC

FWR

1

Temporal

High

57

55

69

75

2

Temporal

Medium

44

49

58

69

3

Temporal

Low

38

44

44

48

4

Non-temporal

High

57

56

69

75

5

Non-temporal

Medium

42

50

60

69

6

Non-temporal

Low

41

44

50

50

7

Coded

High

57

55

69

75

8

Coded

Medium

44

51

56

69

9

Coded

Low

40

46

52

50

NOTE: In positions 7, 8, and 9, temporal coding must be provided by the NAC.
If the NAC voltage is held constant, the horn output will remain constantly on.
Positions 7, 8, and 9 are not available on 2-wire horn/strobe products.

FIGURE 2. LIGHT OUTPUT -

HORIZONTAL DISPERSION

Figures 1-3 list the minimum light output requirements per UL1971.

FIGURE 3. LIGHT OUTPUT - VERTICAL DISPERSION, WALL TO FLOOR

This is generated text for figtxt.

Degrees*

Percent of

Rating

0

100

5-25

90

30-45

75

50

55

55

45

60

40

65

35

70

35

75

30

80

30

85

25

90

25

Compound 45

to the right

24

Compound 45

to the right

24

Degrees*

Percent of

Rating

0

100

5-30

90

35

65

40

46

45

34

50

27

55

22

60

18

65

16

70

15

75

13

80

12

85

12

90

12

Degrees*

Percent of

Rating

0

100

5-25

90

30-45

75

50

55

60

45

65

35

70

35

75

30

80

30

85

25

90

25

*Tolerance of ±1 degree is permitted.

FIGURE 1. LIGHT OUTPUT - VERTICAL DISPERSION, CEILING TO
WALLS TO FLOOR