System Sensor D4240 User Manual

Page 8

Advertising
background image

THREE-YEAR LIMITED W

ARRANTY

Sy

stem Sensor w

arr
ants its enclosed pr

oduct to be fr

ee fr

om defects in materials and

w

orkmanship under normal use and service for a period of thr

ee y

ear
s fr
om date of

manufactur

e. S

ystem Sensor mak

es no other e

xpr
ess w

arr
anty for the enclosed pr

oduct.

No agent, r

epr
esentativ

e, dealer

, or emplo

yee of the Compan

y has the authority to in

-

cr

ease or alter the obligations or limitations of this W

arr
anty

. The Compan

y’

s obligation

of this W

arr
anty shall be limited to the r

eplacement of an

y part of the pr

oduct which

is found to be defectiv

e in materials or w

orkmanship under normal use and service

during the thr

ee y

ear period commencing with the date of manufactur

e. After phoning

Sy

stem Sensor’

s toll fr

ee number 800-SENSOR2 (736-7672) for a R

eturn A

uthorization

number

, send defectiv

e units postage pr

epaid to: S

ystem Sensor

, R

eturns Department, RA

#__________,

3825

Ohio

A

venue
,

St.
Charles

,

IL

60

174.

Please

include

a

note

describing

the malfunction and suspected cause of failur

e. The Compan

y shall not be obligated to

replace units which ar

e found to be

defectiv

e because

of damage

, unr

easonable use

,

modifications

, or alter

ations occurring after the date of manufactur

e. In no case shall the

Compan

y be liable for an

y consequential or incidental damages for br

each of this or an

y

other W

arr
anty

, e

xpr
essed or implied whatsoe

ver

, e

ven if the loss or damage is caused b

y

the Compan

y’

s negligence or fault. Some states do not allo

w the e

xclusion or limitation of

incidental or consequential damages

, so the abo

ve limitation or e

xclusion ma

y not apply

to y
ou. This W

arr
anty giv

es y
ou specific legal rights

, and y

ou ma

y also ha

ve other rights

which v

ary fr

om state to state

.

Please r

efer to inser

t for the Limitations of Fir

e Alar

m Systems

Sensor

2D51

Power Board

At power-up or reset at the panel, the

sensor will take approx 35 seconds

to initialize.

Also occurs if the sensor

has been removed and restored in

the base in the sensor housing.

RED Blink every 5

seconds

Alternating

Green/amber

every 1 second

Supervisory relay

: T

erminals 3 and 14 are closed.

Alarm Relay

: T

erminals 4 and 5 are open.

Aux Relay

does not switch states:

Terminals 6 and 16 are closed,

Terminals 8 and 18 are closed

Sensor is missing during the seven

minute tamper Dela

y, if selected.

O

ff

Alternating

Green/amber

every 1 second

Supervisory relay

: T

erminals 3 and 14 are closed

Alarm Relay

: T

erminals 4 and 5 are open.

Aux Relay

does not switch states:

Terminals 6 and 16 are closed,

Terminals 8 and 18 are closed

Maintenance

Sensor 2D51 is outside it's UL

approved sensitivity limits and needs

to be cleaned or replaced.

RED Blink every 5

seconds

Amber Blink

every 5 seconds

Supervisory relay

: T

erminals 3 and 14 are closed.

Alarm Relay

: T

erminals 4 and 5 are open.

Aux Relay

does not switch states:

Terminals 6 and 16 are closed,

Terminals 8 and 18 are closed

.Unit loses Power

O

ff

O

ff

.Cover

Tamper Delay times out

Green Blink every 5

seconds

Amber solid

.Wiring Problems between the

Sensor and the Power Board

O

ff

Amber solid

.Mismatch between the number of

sensors connected and the Dip

Switch setting

1 sensor connected,2 selected

Green blink every 5

seconds on first

senso

r.

No second senso

r.

LED1 Green

blink every 5

seconds

LED2

Amber

solid

2 sensors connected,1 selected

Green blink every 5

seconds on first

senso

r.

LED's o

ff on second

sensor

LED1 Green

blink every 5

seconds

LED2

Amber

solid

Alarm

Unit detects smok

e

Solid Re

d

Solid Red

Supervisory relay

: T

erminals 3 and 14 are closed

Alarm Relay

: T

erminals 4 and 5 are closed.

Aux Relay

switches states:

Terminals 6 and 16 are open,

Terminals 8 and 18 are open

Standby

Unit has Power and it is not in

initialization,

T

rouble, Maintenance or

Alarm.

Green Blink every 5

seconds

Green Blink

every 5 seconds

Supervisory relay

: T

erminals 3 and 14 are closed

Alarm Relay

: T

erminals 4 and 5 are open.

Aux Relay

does not switch states:

Terminals 6 and 16 are closed,

Terminals 8 and 18 are closed

LED Status

Statu

s

Description

Status of Relays

Supervisory relay

: T

erminals 3 and 14 are open.

Alarm Relay:

Terminals 4 and 5 are open.

Aux Relay

does not switch states with no shutdown on

T

rouble selected:

Terminals 6 and 16 are closed.

Terminals 8 and 18 are closed.

Aux Relay

Switches states with shutdown on

T

rouble selected:

Terminals 6 and 16 are open,

Terminals 8 and 18 are open

Trouble

Sensor

Initialization

TABLE 3. DETECTOR ST

ATUS INDICA

TION

NO
TE: Ther

e ar

e tw

o LED’

s on the P

ow

er boar

d, each indicating the Status of the tw

o sensor

s connected.

When ther

e is only one sensor connected, LED2 will r

emain off.

NO
TE: If an

y other visual indication is noted contact S

ystem Sensor technical support at 1-800-SENSOR2.

SS-300-022

8 I56-3936-003R

©2012 System Sensor

Advertising