D100-55-00

3

I56-733-10

Volt D.C. power supply to a 4" square junction box 2-1/8" deep only.
(If necessary, add an extension ring if the selected box does not have
adequate volume.) The power supply may be mounted remotely from
the detector.

All wiring must be performed by a licensed electrician and installed in
compliance with the National Electrical Code, applicable local codes,
and any special requirements of the local authority having jurisdiction.

Use only the specified wire gauge. Maximum interconnect bus length
is 5,000 feet, #18 AWG or larger two-conductor stranded cable.

The detector includes a tamper-resist feature that, when activated, re-
quires a tool for detector removal. The following detector installation
instructions include how to activate this feature.

Installation Instructions

1. Turn off power at main service panel.
2. Using wire connectors, attach either black wire from power supply to

black AC power wire. Attach other black wire from power supply to
white AC neutral wire.

3. Using wire connectors, connect red and gray power supply output

wires to the bus line wires supplying power to the remote detectors.
(See Figure 7.) Use color-coded bus wires.

4. Mount power supply to junction box and cover junction box with a 4"

square box cover, using box mounting screws.

5. Install a junction box where you plan to install the detector. (See type

and size for junction box above.)

6. Install bus line wires from power supply output to junction box. Use

#14-18 AWG wire only. See Figure 7 to determine maximum power bus
length for wire size and number of interconnected detectors.

7. Connect color-coded DC power bus wires to power input screw termi-

nals, located on detector back. If detectors will be interconnected or the
relay used, see following sections for specific installation instructions.

8. Remove detector from mounting bracket by turning the detector

counter-clockwise and pulling the detector away from the bracket.

9. Remove small tab on mounting bracket to activate tamper-resist fea-

ture, if desired. (To release a detector with this feature, push up on

locking tab with screwdriver while turning detector counterclockwise.)

10. Install mounting bracket to junction box.
11. Connect power wires to detector(s) as shown in Figure 8. Be sure to

tighten each terminal screw to secure wire in place. Tug wire to be sure
it is connected properly.

12. Attach smoke detector to mounting bracket by aligning arrows on side

of mounting bracket 1-inch to the right of the nib on the detector. Ro-
tate until the arrow and nib line up. (See Figure 8).

13. After installing all detectors, turn on power at the main service panel.
14. Check for the green LED to flash about once every 30 to 40 seconds.

This means the detector is receiving power. Check all detectors.

Note:

If the LED does not flash, power is not getting to the smoke detec-
tor. Check wiring. If LED still does not flash, return the smoke de-
tector to the manufacturer for repair.

15.Test each detector in the system. (See “Testing” below for more de-

tailed instructions.)

A78-2187-01

(–)

(+)

INTERCONNECT UP TO
12 DETECTORS

AUXILIARY

ALARM RELAY

12OVAC

A77-727-O1

12VDC POWER

SUPPLY

POWERS UP TO

16 DETECTORS

GRAY

RED

BLACK

BLACK

WIRE

GAUGE

14AWG
16AWG
18AWG

1 UNIT

5000
3735
2349

2 UNITS

2970
1867
1174

3 UNITS

1980
1245

783

4 UNITS

1485

933
587

5 UNITS

1188

747
469

6 UNITS

990
622
391

Maximum power bus length in feet, given number of units (maximum per bus) and wire size.

Maximum interconnect bus length: 5,000 FT., No. 18AWG or larger dual conductor cable.
All wiring must conform to local electrical codes.
Relay contacts rating: 0.5A 30VDC; 0.5A 30VAC

7 UNITS

848
533
335

8 UNITS

742
466
293

9 UNITS

660
415
261

10 UNITS

594
373
234

11 UNITS

540
339
213

12 UNITS

495
311
195

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

GROUND

SIGNAL

(+) (–)

POWER INPUT

AUXILIARY

A78-2012-00

ALIGNMENT

ARROW

FOR TAMPER RESIST
BREAK OFF TAB HERE

REMOVE

INSTALL

WHEN INSTALLING:
ALIGN ARROWS ON MTG.
BRACKET 1" TO THE
RIGHT OF THE NIB ON
THE DETECTOR. ROTATE
UNTIL ARROW AND NIB
LINE UP.

MOUNTING
SCREW

MOUNTING
BRACKET

MOUNTING
SCREW

Figure 8:

Dimensions
1-3/4" high
5-1/2" base dia.

Figure 7:

Advertising