Prior to first use of Ice/Water

Dispenser

C

Water mains pressure must not be

below 1 bar.

C

Water mains pressure must not be

over 8 bars.

C

Pumps must be used in case the

supply water pressure drops below 1
bar or if a jug is going to be used.

C

Water system of the refrigerator

must be connected to the cold water
line. It must not be connected to hot
water line.

C

No water may be obtained in the

initial startup of the refrigerator. This
is caused by the air in the system. To
discharge air from the system, press
Dispenser latch for periods of 1 minute
until water comes from the Dispenser.
Water flow may be irregular in the
beginning. Irregular water flow will be
normalized after the air in the system is
discharged.

C

At the initial startup of the

refrigerator approx.12 hours must pass
before cold water can be obtained.

C

Water mains pressure must be

between 1-8 bars for the operation
of Ice/Water Dispenser smoothly. For
this, check that 1 glass of water (100
cc) can be filled in 10 seconds.

C

The first 10 glasses of water should

not be consumed.

C

12 hours must pass to obtain ice

from the Ice Dispenser for the first
time. If there is not enough ice in the
ice dispenser, ice may not be obtained
from ice dispenser.

C

Approximately the first 30 cubes

of ice to be obtained from the Ice
Dispenser must not be used.

C

Always use the water filter when a

jug is not being used.