Alto-Shaam 300-HW/D443 User Manual

Page 17

Advertising
background image

S E R V I C E

Hot Food Drop-In Well Operation & Care Manual • 15

CALIBRATION PROCEDURES

Every unit is calibrated at the factory. Only a qualified

service technician should calibrate the unit in the field

if necessary.
SHOCK RISK WARNING:

Unit must be disconnected

from power source before making adjustments or

calibrating switch.
TOOLS REQUIRED:

2mm allen (hex) wrench

D A N G E R

DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.

LOC

P/N

DESCRIPTION

1.

CD-3232

CORDSET 120V (100-HW & 200-HW)

2.

CD-33367

CORDSET 120V (300-, 400- & 500-HW)

3.

CD-33840

CORDSET 208-240V

4.

CD-3922

CORDSET 230V

5.

LI-3027

WHITE POWER LIGHT 110V

6.

LI-3951

WHITE POWER LIGHT 250V

7.

PE-29421

PANEL OVERLAY 1-10

8.

TT-34982

THERMOSTAT, 120V

9.

TT-34981

THERMOSTAT, 240V

10.

KN-26568

KNOB

1

2

5

6

7

8

9

3

CABLE HEATING REPLACEMENT SERVICE KITS

100-HW

200-HW 300-HW

400-HW

500-HW

KIT NUMBER

4877

4878

4880

4881

5

4880

SERVICE KIT INCLUDES:

CB-3045

CABLE HEATING ELEMENT

37 ft

67 ft

132 ft

144 ft

120 ft

CR-3226

RING CONNECTOR

2

4

8

12

8

IN-3488

INSULATION CORNER

8 ft

8 ft

8 ft

8 ft

8 ft

BU-3105

SHOULDER BUSHING

2

4

8

12

8

BU-3106

CUP BUSHING

2

4

8

12

8

SL-3063

INSULATING SLEEVE

2

4

8

12

8

TA-3540

HIGH TEMP ELECTRICAL TAPE

1 roll

1 roll

1 roll

1 roll

1 roll

ST-2439

10.32 STUD

2

4

8

12

8

NU-2215

HEX NUT

4

8

32

24

32

Part numbers and drawings are subject to change without notice .

SERVICE PARTS

4

10

Advertising