:MARKer (?)

<mark_sclk>

64e6,100e-3,100e6

:VOLTage (?)

{<ampl>|MINimum|MAXimum}

5,10e-3,10

:OFFSet (?)

<offs>

0,-3.6,3.6

:SINusoid

:PHASe (?)

<phase>

0,0,360

:TRIangle

:PHASe (?)

<phase>

0,0,360

:SQUare

:DCYCle (?)

<duty_cycle>

50,1,99

:PULSe

:DELay (?)

<delay>

10,0,99.9

:WIDTh (?)

<pulse_width>

10,0,99.9

:TRANsition (?)

<rise>

10,0,99.9

:TRAiling (?)

<fall>

10,0,99.9

:RAMP

:DELay (?)

<delay>

0,0,99.9

:TRANsition (?)

<rise>

60,0,99.9

:TRAiling (?)

<fall>

30,0,99.9

:SINC

:NCYCle (?)

N_cycles>

10,4,100

:GAUSsian

:EXPonent (?)

<exp>

20,10,200

:EXPonential

:EXPonent (?)

<exp>

-20,-100,+100

:DC (?)

<%_amplitude>

100,-100,+100

APPLy:SINusoid{<freq>,<ampl>,<offs>,<phase>}

Purpose
This command is a high-level command that programs the PXA125 to output sine waveform along with its
associated parameters

<freq> sets the output frequency in units of hertz

<ampl> sets the output amplitude in units of volts

<offs> sets the output offset in units of volts

<phase> sets the output start phase in units of degrees

Parameter type

Numeric

Parameter range

<freq>

10e3 to 50e6

<ampl>

80e-3 to 8

<offs>

-3.6 to +3.6

<phase>

0 to 360

APPLy:SINusoid?

Response
The PXA125 will return <freq>, <ampl>,<offs>,<phase>. Default values are

1e6,5,0,0

APPLy:TRIangle{<freq>,<ampl>,<offs>,<phase>}

Advertising