Scope


The scope of this document is to familiarize the user with various sections of the Device Compliance Test
where IUT interaction is required. This document should allow the user to prepare for these tests in
advance.

Description


Compliance Test program includes three test categories which require interaction from IUT. These are
DS_XX (device status test), MP_XX (General Component Protocol checklist of master) and 1.XX
(Component Protocol checklist for a master device) tests. All other tests are performed automatically.

In these tests the TA660 is used as target and the IUT is the master. The TA660 as a target device needs to
have three different addresses for Memory, I/O and Configuration spaces where master (IUT) can read and
write to these addresses. These addresses must be free from use by other agents in the system therefore the
TA660 software searches the system at the beginning of the compliance test and finds the addresses which
TA660 can use. So long as the system under test has not changed configuration these addresses should stay
the same for use for TA660 during the Device Compliance Test.

Most of the time the Memory address found for TA660 is at 0x10000000 and free I/O address is at
0x10000000. Please note this may change depending on system configuration and address assignment by
the BIOS.

To find which addresses are free for TA660 as target in advance the user may select and execute test 1.09
(press cancel at each message not to execute the test if only verifying the address assignment for TA660).

In the example below all memory, I/O and Configuration addresses are all assigned to be 0x10000000