19 update device – Teledyne LeCroy Sierra M122 User Manual User Manual

Page 215

Advertising
background image

    

Sierra M122 SAS/SATA Protocol Analyzer User Manual

213

Update Device

  Teledyne LeCroy

Note:

The External TrigOut pulse width field supports increments of 16 ns, starting from 64 ns and 

up to 1024 ns.

External Trig In Setting
An external Low or High input signal can cause triggering. Select the 
External Trig In Setting: High Active, Low Active, or Toggle from High to Low or Low to 
High once (3.3 V output).

Note:

The nominal External Trigger voltage is 0.818 volts. Trigger In can work with 1 volt to 5 volts 

input voltage.

3.19 Update

Device

The Update Device command allows you to update a Sierra M122 Analyzer or CATC‐Sync 
expansion card whose current version is incorrect.

1. Click Setup > Update Device to display the Device Setup dialog.

Figure 3.142: Device Setup Dialog with BAD Device Status

Devices whose version is correct have an OK status. 
A device whose version is incorrect has a BAD status.

Note:

You can click the ellipses (...) at the end of a file path and name to display an Open dialog, in 

which you can browse for files.

2. Click the checkbox to the left of a device with BAD status, then click Update Selected 

to begin the process that will make the Analyzer version correct (see figure on next 
page).