Creating Global Rules

256

 

 

Sierra M122 SAS/SATA Protocol Analyzer User Manual

3. Click the prompt to add another event (keep in mind this is not a combined event).

Figure 4.32: Example 6: Entering the Second Event

The Event Properties dialog box displays.

4. In the Type column on the left, choose Timer. Set the timer for random timing with a 

maximum time limit of 1.790 seconds.

5. Click OK to close the Event Properties dialog box.
6. Click the prompt to add an action to correspond with the second event.

Figure 4.33: Example 6: Entering Second Action

The Action Properties dialog box appears.

7. In the Type list on the left, choose Stop Scenario as the action that you want after 

the timer has expired.