QPHY-SAS2 Software Option

917718 Rev

A

15

USING THE LECROY SIERRA M6 FOR SAS TRANSMITTER TESTING

The LeCroy Sierra M6 protocol analyzer can be used to stimulate SAS-2 targets to output the required test
patterns for SAS-2 transmitter testing.

Required Equipment

LeCroy Sierra M6-4 or M6-2 SAS Protocol Analyzer

LeCroy Protocol Suite Utility is required to control the Sierra

This is available from www.lecroy.com.

Wilder Tech SAS-TPA-R Test Fixture (or equivalent)

SDA 813Zi Oscilloscope (see compatibility section for other valid oscilloscope models)

QPHY-SAS2 option required

2 high quality, short, matched SMA cables as described above

DC Blocks , qty =2

<=10MHz to >=18GHz DC block are required for SAS2 testing (e.g Pasternack PE8210)

TF-SATA-C-Kit (including 4 small cables, SSMP to SMA female)

1 SATA cable (for connection to the SIERRA M6)

Sierra configuration files: sas2 phy diagnostic page.sac, SAS2_PortA_Diagnostics.txt and
SAS2_PortB_Diagnostics.txt files (available from www.lecroy.com)

Figure 7 - Connection Diagram when using Sierra to control DUT