Vestil ABLT-H-LP User Manual

Page 4

Advertising
background image

rev. 12/14/2012

ABLT-H, Manual

Page 4 of 5


1. Check clamps and hose connections periodically. Verify that all connections are airtight.
2. Inspect all moving parts to confirm normal motion, cleanliness, and state of wear. If any part

is excessively worn, immediately tag the unit “OUT OF SERVICE” and report the issue to
maintenance personnel.

LOCKOUT/TAGOUT Procedure: Press the lever arm down to cut off air to the system
(see FIG. 4 on p. 3); then attach a padlock to the lever arm through the opening in the
lever arm.

3. Clean the air filter element at least every 3 months.
4. Grease and oil all pivot points and shafts at least every 3 months. Lubricate all pivot points

at least once per day if the table is in high cycle operation. Use 90-weight gear lube (SAE
85W 140 EP) to lubricate pivots and shafts.

5. Grease the upper and lower roller channels.
6. Lubricate pivot points of the lock mechanism.

Advertising