Lift cylinder changeout instructions – Vestil EPT-30 User Manual

Page 98

Advertising
background image

98

Filename: Changing Cylinder in EPT VESTIL MFG. CO.
5/09/07 TG Model: EPT-XXXX-30

15-126-014

Instructions for Changing the Cylinder in EPT-XXXX-30; estimated time, 45 min.

READ ALL INSTRUCTIONS BEFORE PROCEEDING!

Only qualified personnel should work on this equipment!

Lock out all potential energy sources before attempting this installation. Make sure the
forks are fully lowered; turn off the unit and remove the key.

Warning!

!

Working with or near lead acid batteries is dangerous. Batteries contain sulfuric

acid and produce explosive gases. A battery explosion could result in loss of
eyesight or serious burns.

!

Do not smoke or allow a spark or flame near batteries. Charge batteries in

locations which are clean, dry, and well-ventilated. Do not lay tools or anything
metallic on top of any battery. All repairs to a battery must be made by experienced
and qualified personnel.

!

When working with batteries, remove personal items such as rings, bracelets,

necklaces, and watches. Batteries can produce enough energy to weld jewelry to
metal, causing a severe burn.

!

Always have fresh water and soap nearby in case battery acid contacts skin, clothing,

or eyes.

!

Operating the battery with a low battery voltage can cause premature motor

contact failure.

!

Do not expose the lift or charger to rain or adverse conditions.

!

Replace defective cords or wires immediately.

!

Check the battery’s water level frequently if this applies to your battery type.

!

Make sure the battery charger is unplugged from 115vac source.

Troubleshooting:

If the cylinder is leaking, and needs replaced or seals replaced; continue with the

following procedure.


Tools Required:
14mm wrench, 16mm wrench, or crescent wrench
Regular flat bladed screw driver
“Dental Pick” for o-rings