Use instructions – Vestil PG series User Manual

Page 11

Advertising
background image

Use Instructions:

The operating instructions in this manual are meant to supplement the operating

recommendations of the ASME that appear in B30.20.

Only trained, designated persons should use the Pipe grab. “Designated person” means someone
selected by his or her employer, or by a representative of the employer, as competent to use the pipe
grab. Trainees under the direct supervision of a designated person may use the device. Maintenance
and personnel who perform tests also may use the pipe grab when necessary for the performance of their
employment duties.

Step 1: Connect the Pipe Grab to the hoisting device that will be used. The pipe grab should be
connected to the hoist with a safety hook to prevent accidental detachment from the hoist.

Safety Hook

Properly functioning safety latch

Step 2: Test the pipe grab for normal function. Lift each of the stabilizing/releasing arms to verify that the
grab opens and closes smoothly.

2

1

Step 3: Move the pipe grab into position above the load.

Step 4: Grasp the object. Lift one of the pipe guide weldments to open the grab (photo 5), and while
open, lower the grab around the object (photo 6). Lower the pipe guide weldment until the load-engaging
portions of both arms (identified in FIG. 1) contact the top of the load material (circled in photo 7).

5

6

- 11 -