• Part No. 25058 / 250C-IG-24V Compressor Kit

(CE Spec.)

Motor Voltage:

24 Volts

Max. Current Consumption:

5 Amps

Motor Type:

Permanent Magnetic

Horsepower:

1/4

Max. Working Pressure:

150 PSI

Max. Duty Cycle (@ 72°F & 100 PSI):

100%

Minutes On/Off (@ 72°F & 100 PSI):

Continuous

Max. Restart Pressure:

150 PSI

Max. Ambient Temperature:

158°F

Min. Ambient Temperature:

-40°F

Auto. Reset Thermal Protection:

Yes

Dimensions:

7.6”L x 4”W x 6.75H”

Net Weight:

6.75 Lbs.

COMPRESSOR APPLICATION GUIDE

To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to

information below:

VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES

DUTY CYCLE

WORKING PRESSURE

100 SERIES

15%

130 PSI

275 SERIES

25%

150 PSI

280 SERIES

30%

150 PSI

325 SERIES

33%

150 PSI

350 SERIES

100%

150 PSI

380 SERIES

100%

200 PSI

400 SERIES

33%

150 PSI

450 SERIES

100%

150 PSI

480 SERIES

100%

200 PSI

ABOUT COMPRESSOR DUTY CYCLE:

Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time

period, at 100 PSI and at a standard ambient temperature of 72°F. Duty Cycle is commonly

expressed in percentile as:

Compressor on Time/ (Compressor on Time + Off Time) %

As an example, a compressor that is rated for 25% duty cycle means that compressor can be

operated at:

100 PSI @ 72°F for 10 Minutes ON and 30 Minutes OFF

10 Min. On / (10 Min. On + 30 Min. Off) = 10 Min. / 40 Min.

=25% Duty Cycle

DUTY CYCLE REFERENCE CHART

DUTY CYCLE @100PSI / 72°F

MINUTES ON / OFF

15%

6 Min. On / 34 Min. Off

20%

8 Min. On / 32 Min. Off

25%

10 Min. On / 30 Min. Off

30%

13 Min. On / 30 Min. Off

33%

15 Min. On / 30 Min. Off

100%

Continuous Duty