Single “c” model compressor wiring diagram, User manual 250c-ig compressor kit – VIAIR 250C-IG User Manual

Page 6

Advertising
background image

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated

working pressure of the compressor. Never use a pressure switch with a higher cut-off pressure

than compressor’s rated working pressure.

WIRE GAUGE GUIDE 12-VOLT:

WIRE GAUGE GUIDE 24-VOLT:

USER MANUAL

250C-IG COMPRESSOR KIT

Amp Draw

Length of wire from battery to compressor

10

15

20

25

30

10

14

12

10

10

10

15

12

10

10

8

8

20

10

10

8

6

6

25

10

8

6

6

6

30

10

8

6

6

4

40

8

6

6

4

4

50

6

6

4

4

2

60

6

4

4

2

2

Amp Draw

Length of wire from battery to compressor

10

15

20

25

30

10

18

16

14

12

12

15

16

14

12

12

10

20

14

12

10

10

10

25

12

12

10

10

10

30

12

10

10

8

8

40

10

10

8

6

6

50

10

8

6

6

6

60

10

8

6

6

4

Wiring Diagram:

(Fuse Not Included)

SINGLE “C” MODEL

COMPRESSOR WIRING DIAGRAM

15 Edelman

Irvine, CA 92618

949-585-0011

www.viaircorp.com

87

86

30

85

+

-

Battery

To Keyed

Power Source

12V 40A

Relay

Fuse

Pressure

Switch

Rev.1

Advertising