Configuring Communication

67

7" Modero Widescreen Touch Panels

Master Connection section - Virtual Master communication over Ethernet

Before beginning:

1.

Verify the panel has been configured to communicate either through an Ethernet cable

(connected from either the panel to a valid Ethernet Hub) or wireless to the Wireless Access

Point.

2.

Launch NetLinx Studio 2.3 (default location is Start > Programs > AMX Control Disc >

NetLinx Studio > NetLinx Studio 2.3).

3.

Select Settings > Master Communication Settings, from the Main menu to open the Master

Communication Settings dialog (FIG. 62).

4.

Click the Communications Settings button to open the Communications Settings dialog.

FIG. 61 System Connection page

Obtained

from

NetLinx

Master

When configuring your panel to communicate with a Virtual Master (on your PC) via
Ethernet, the Master IP/URL field must be configured to match the IP Address of the
PC and make sure to use the Virtual System value assigned to the Virtual Master
within NetLinx Studio.

FIG. 62 Assigning Communication Settings and TCP/IP Settings for a Virtual Master

IP Addresses of computer
(also obtained by using the
Start > Run > cmd command)

Enter this IP

into the

Master IP/URL

field on the

System Connection

page