Warner Electric CBC-200C Single User Manual

Page 10

Advertising
background image

10

Warner Electric • 800-825-9050

P-269 • 819-0407

CBC-200-C2
External Level Adjust with Internal
Current Limit Adjust

1. Wire the external level adjust
potentiometer on Terminal Block TB-2 as
shown in the diagram. (See Figure 5)

2. If the accessory pot kit is used, then wire
according to the colors as shown in the
diagram

3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.

Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.

CBC-200-3
External Current Limit and Level Adjust

1. Wire the external current limit adjust
potentiometer to Terminal Block TB-3 for
Channel 1 as shown in the diagram. (See
Figure 7)

2. If the accessory pot kit is used, wire per
the color codes as shown.

3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.

4. Wire the external level adjust
potentiometer to Terminal Block TB-2 as
shown in the diagram. (See Figure 7)

5. If the accessory pot kit is used, wire per
the color codes as shown.

6. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out.

Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.

Chassis Mount Models
CBC-200-C1
CBC-200-C2
CBC-200-C3

1. The CBC-200-C series chassis mount
version controls are shipped with the face
plate bracket assembly loose.

2. Wire the control per the appropriate Wiring
configuration for the type of external
potentiometer being used.

3. Based on which model used, route the pot
cable accordingly. Make sure to keep the
cable away from components which may get
hot during operation or points where the
cable may become pinched. Refer to the
wiring diagrams for the proper connection.

4. After the pot(s) have been wired to the
appropriate terminal blocks, mount the PCB
and bracket assembly and attach to the
mounting surface with the four screws
provided.

CBC-200-C1 External current limit
adjustment

1. Wire the external current limit
potentiometer to Terminal Block TB-3 for
Channel 1 as shown in the diagram. (See
Figure 6)

2. If the accessory pot kit is used, wire per
the colors as shown in the diagram.

3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.