Warner Electric CBC-200C Single User Manual

Page 9

Advertising
background image

9

Warner Electric • 800-825-9050

P-269 • 819-0407

CBC-200-2
External Level Adjust with Internal
Current Limit Adjust

1. Wire the external level adjust potentiome-
ter on Terminal Block TB-2 as shown in the
diagram. (See Figure 5)

2. If the accessory pot kit is used, wire
according to the colors as shown in the
diagram.

3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.

Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.

4. After the pot(s) has been wired to the
appropriate terminal block, mount the PCB
and bracket assembly and reattach to the
chassis with the four screws removed in step
2 above.

5. For the CBC-200-2 reattach the internal
potentiometer knob.

6. Double check all wiring for both the
potentiometer and the main terminal block
to insure proper connections.

CBC-200-3
External Current Limit and Level Adjust

1. Wire the external current limit adjust
potentiometer to Terminal Block TB-3 for
Channel 1 as shown in the diagram.
(See Figure 7)

2. If the accessory pot kit is used, wire per
the color codes as shown.

3. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.

4. Wire the external level adjust potentiome-
ter to Terminal Block TB-2 as shown in the
diagram. (See Figure 7)

5. If the accessory pot kit is used, wire per
the color codes as shown.

6. Make sure all terminals are securely
fastened and the wiring cable is secured so
that it can’t pull out of the terminals.

Note: The level adjustment controls both the
current adjustable output, channel 1 as well as
the steady state output, channel 2.

Advertising