Warner Electric CBC-1550AHFC User Manual

Page 19

Advertising
background image

19

Warner Electric • 800-825-9050

819-9050

CBC1500AHFC and CBC1550AHFC Revision B Installation Procedure

To prevent personal injury, ensure all personnel are clear of conveyor line and the

pusher before performing any adjustments on the control.

Programming Adjustments

1.

Turn on the power switch of the control. The power switch should illuminate.

2.

On the control display, press #2 (MOV-PST). The number 600 should be displayed on the LED display.
If any other number is displayed, do the following:
a) Press “EDIT” (the word edit should be displayed on the LED display).
b) Press “CLEAR” (all numbers should reset to zero).
c) Enter 600.
d) Press “EDIT” (the word edit should turn off).

3.

Press #1 (COUNT) on the control.

4.

Set the toggle switch on the control marked RUN/JOG to JOG position.

5.

Press the “CLUTCH-JOG” switch and release immediately. Make sure the pusher is moving in the right
direction for its configuration. If not, remove power from the system (including power from the motor) and
swap the motor phase wires.

Note: I f t he cont r ol i s count i ng negat i ve number s, swap Si gnal A and Si gnal B i nput s
i n t he War ner El ect r i c cont r ol .
6.

Jog pusher until the long arm is straight and both paddles are inside the pusher enclosure.

7.

Press #1 (COUNT) on the control.

8.

Press “CLEAR” (all numbers should reset to zero).

9.

Jog the pusher slowly as you watch the lower left side of the display. When you see “ref” light come on,
stop and note what number is in the display. This is your “home reference”. The “home reference” will have
to be entered into the control in a later step.

Note: The “ r ef ” l i ght must be seen bet ween 100 and 500 pul ses. I f t he “ r ef ” si gnal
i s not seen unt i l beyond t hi s r ange, t he encoder wi l l have t o be di smount ed r ot at ed
l ef t or r i ght 90 degr ees and r emount ed. Once t he encoder has been r emount ed r epeat
st ep #9.
10.

On the control display, press “RUN/PGM”.

11.

Enter 1000.

12.

Press the down arrow.

13.

The first line of the program should be displayed, showing the home reference “h” and a value (this value
could be zero).

14.

Press “CLEAR”.

15.

Enter the “home reference” you recorded in step #9.

16.

Press the arrow down key.

bd

(25 to 75)

Braking distance average

If it is not in that range:
Press “RESET/CLEAR”

bd

0

Clearing to set new value

Press key 6.

bd

60

Braking set: 60 encoder pulses

17.

Press the arrow down key.

bd. AuE. 3

Number of cycles averaged = 3

18.

Press the arrow down key.

cc. 0.5000

Count Correction Feature

19.

Press the arrow down key.

dP.

off

Decimal Point Feature is off.

20.

Press the arrow down key.

FrSt.

on

Front panel reset is enabled.

21.

Press the arrow down key.

PLoc.

off

Front panel lockout is off.

22.

Press the arrow down key.

CrEt.

off

Count retention should be off.

If it says CrEt on:
Press the arrow right key.

CrEt.

off

Count retention is now back off.

23.

Press the arrow down key.

ArSt.

on

Auto reset should be on.

If it says ArSt. Off:
Press the arrow right key.

ArSt.

on

Auto reset is now back on.

24.

Press the arrow down key.

01

00.20

Start signal of 200ms.

If it is not 00.20:
Press “RESET/CLEAR”

01

LAtch

Press key 2.

01

00.02

Advertising