Parts List for kit 5200-101-011

Item Quantity

Part Name

1

1

Bracket

2

4

Screw, Flat Head

3

1

Box, Conduit

4

1

Plug, Protective

5

2

Grommet, Wire

6

2

Spacer, Terminal

*7

2

Cap, Terminal

8

1

Screw, Hex, Washer Head
Green

8-1

1

Ring, Terminal

*9

2

Screw, No. 8 Brass

*9-1

2

Ring, Terminal

10

1

Cover

11

1

Screw, Hex, Washer Head

12

1

Plug, Protective

*Item 7 - Cap, Terminal, Item 9-1 - Ring, Terminal, and Item 9 - Screw, No.

8 Brass, are provided in terminal Accessory Kit 5311-101-001.

Note: All mounting screws are self-tapping.

Introduction

Conduit box kit No. 5200-101-011 plus field/
magnet terminal accessory kit, contains all
components needed to assemble a conduit box
for PB-825, 1000, 1225, 1525, EB-825, 1000,
1225, EC-1000, 1225 clutches and brakes. This
conduit box will provide a proper means for wiring
terminations and conforms to the requirements of
Underwriters Laboratories.

Failure to follow these

instructions may result in product damage,

equipment damage, and serious or fatal injury

to personnel.

Do not connect rigid conduit

directly to the conduit box. A minimum of 12”

of flexible liquid tight conduit or other suitable

flexible wiring with appropriate fittings is

required. Flexible conduit is required to prevent

side loading of bearing on bearing mounted

clutches and brakes and possible deformation

of the conduit box or clutch/brake components

during assembly.

Step 1
Assemble a customer supplied flexible wiring
connector into the desired end of the conduit box
(3). Press protective plug (4) into unused conduit
hole.

Thread green washer head hex screw (8) into round
hole in base of conduit box. Place terminal ring (8-1)
over screw before inserting.

Snap two wire grommets (5) into square holes in
conduit box base. The grommet crowns should be
toward the outside of the box and the rubber
flanges should be on both sides of the conduit box.

Push two terminal spacers (6) through rubber
grommets. (See Figure 1)

11

10

*7

*9

*9-1

6

3

5

4

8

8-1

12

2

1

Components

Figure 1