A major rebuild of an AT brake can be
accomplished by following these instructions to
replace the parts furnished in the appropriate
Warner Electric brake rebuild kit. Proceed
as follows:

1. Turn off all power to machine and brake using

appropriate electrical lockout procedures.

2. Disconnect the brake coil wires from the

incoming control unit wires, and remove
optional conduit box from brake if used.

3. Disconnect the anti-rotation torque arm from

the magnet.

4. Loosen the hub set screws holding brake on

shaft.

5. Remove the brake from its shaft by pulling

and/or gently tapping the hub with a hammer
and drift.

Note: Do not hit the outer portion

of the brake outboard of the hub as this may
severely damage it.

6. Remove retaining ring.